Time synchronization for banks and trading platforms: MiFID II
In the financial sector, time is no detail. Every order, change, and transaction is time-stamped, and regulators must be able to reconstruct the exact sequence of events retrospectively. The European MiFID II rules therefore impose strict requirements on the clocks of trading platforms and their participants.
What does MiFID II require?
Technical standard RTS 25 under MiFID II stipulates that business clocks providing timestamps must be synchronized with UTC, the Global Reference Time. The degree of accuracy depends on the type of trade:
High-frequency algorithmic trading: maximum deviation of 100 microseconds from UTC, with a timestamp to within 1 microsecond.
Other algorithmic trading: maximum 1 millisecond deviation.
Transaction via voice or human intervention: maximum deviation of 1 second.
In addition, an organization must be able to demonstrate that its time is traceable to UTC. This means documenting the design, operation, and specifications of the system and verifying this periodically.
How do you achieve that accuracy?
A proprietary, traceable time source: a time server with GNSS reception as a reference, in your own data center.
The right protocol: for 1 millisecond, NTP is usually sufficient on a well-configured network. For 100 microseconds or better, PTP with hardware timestamps is the standard choice. View our NTP and PTP time servers .
Redundancy and holdover: two independent time servers and a stable oscillator that retains the time if the satellite signal drops out.
Monitoring and logging: monitor the deviation of each server from the reference and retain that data as evidence.
Not only for trading platforms
Outside of trading, banks also require reliable time: for payment transactions, security logging, access systems, and clocks in offices and dealing rooms. For dealing rooms, BerdoTime also supplies Wharton time zone clocks that display the time of multiple exchanges simultaneously.
This article is a technical explanation and not legal advice.
Need advice?
BerdoTime advises on time servers, PTP grandmasters, and redundant setups for the financial sector. Call 085-4000265 or email info@berdo.nl .



Comments